@ -291,6 +291,11 @@ void tzc400_enable_filters(void) |
|
|
|
for (filter = 0U; filter < tzc400.num_filters; filter++) { |
|
|
|
state = _tzc400_get_gate_keeper(tzc400.base, filter); |
|
|
|
if (state != 0U) { |
|
|
|
/* Filter 0 is special and cannot be disabled.
|
|
|
|
* So here we allow it being already enabled. */ |
|
|
|
if (filter == 0U) { |
|
|
|
continue; |
|
|
|
} |
|
|
|
/*
|
|
|
|
* The TZC filter is already configured. Changing the |
|
|
|
* programmer's view in an active system can cause |
|
|
@ -312,14 +317,17 @@ void tzc400_enable_filters(void) |
|
|
|
void tzc400_disable_filters(void) |
|
|
|
{ |
|
|
|
unsigned int filter; |
|
|
|
unsigned int state; |
|
|
|
unsigned int start = 0U; |
|
|
|
|
|
|
|
assert(tzc400.base != 0U); |
|
|
|
|
|
|
|
/*
|
|
|
|
* We don't do the same state check as above as the Gatekeepers are |
|
|
|
* disabled after reset. |
|
|
|
*/ |
|
|
|
for (filter = 0; filter < tzc400.num_filters; filter++) |
|
|
|
/* Filter 0 is special and cannot be disabled. */ |
|
|
|
state = _tzc400_get_gate_keeper(tzc400.base, 0); |
|
|
|
if (state != 0U) { |
|
|
|
start++; |
|
|
|
} |
|
|
|
for (filter = start; filter < tzc400.num_filters; filter++) |
|
|
|
_tzc400_set_gate_keeper(tzc400.base, filter, 0); |
|
|
|
} |
|
|
|
|
|
|
|