Browse Source

docs/library/machine.UART: Remove conditional docs for wipy port.

The UART.init() method is now included unconditionally and its wording
adjusted to better describe ports other than the cc3200.

UART.irq() is also included unconditionally, but this is currently only
available on the WiPy target.
pull/3948/merge
Damien George 6 years ago
parent
commit
4cc65e22d4
  1. 38
      docs/library/machine.UART.rst

38
docs/library/machine.UART.rst

@ -43,21 +43,27 @@ Constructors
Methods
-------
.. only:: port_wipy
.. method:: UART.init(baudrate=9600, bits=8, parity=None, stop=1, \*, pins=(TX, RX, RTS, CTS))
.. method:: UART.init(baudrate=9600, bits=8, parity=None, stop=1, \*, ...)
Initialise the UART bus with the given parameters:
- ``baudrate`` is the clock rate.
- ``bits`` is the number of bits per character, 7, 8 or 9.
- ``parity`` is the parity, ``None``, 0 (even) or 1 (odd).
- ``stop`` is the number of stop bits, 1 or 2.
- ``pins`` is a 4 or 2 item list indicating the TX, RX, RTS and CTS pins (in that order).
- *baudrate* is the clock rate.
- *bits* is the number of bits per character, 7, 8 or 9.
- *parity* is the parity, ``None``, 0 (even) or 1 (odd).
- *stop* is the number of stop bits, 1 or 2.
Additional keyword-only parameters that may be supported by a port are:
- *tx* specifies the TX pin to use.
- *rx* specifies the RX pin to use.
On the WiPy only the following keyword-only parameter is supported:
- *pins* is a 4 or 2 item list indicating the TX, RX, RTS and CTS pins (in that order).
Any of the pins can be None if one wants the UART to operate with limited functionality.
If the RTS pin is given the the RX pin must be given as well. The same applies to CTS.
When no pins are given, then the default set of TX and RX pins is taken, and hardware
flow control will be disabled. If pins=None, no pin assignment will be made.
flow control will be disabled. If *pins* is ``None``, no pin assignment will be made.
.. method:: UART.deinit()
@ -109,17 +115,15 @@ Methods
Send a break condition on the bus. This drives the bus low for a duration
longer than required for a normal transmission of a character.
.. only:: port_wipy
.. method:: UART.irq(trigger, priority=1, handler=None, wake=machine.IDLE)
Create a callback to be triggered when data is received on the UART.
- ``trigger`` can only be ``UART.RX_ANY``
- ``priority`` level of the interrupt. Can take values in the range 1-7.
- *trigger* can only be ``UART.RX_ANY``
- *priority* level of the interrupt. Can take values in the range 1-7.
Higher values represent higher priorities.
- ``handler`` an optional function to be called when new characters arrive.
- ``wake`` can only be ``machine.IDLE``.
- *handler* an optional function to be called when new characters arrive.
- *wake* can only be ``machine.IDLE``.
.. note::
@ -134,9 +138,13 @@ Methods
Returns an irq object.
Availability: WiPy.
Constants
---------
.. data:: UART.RX_ANY
IRQ trigger sources
Availability: WiPy.

Loading…
Cancel
Save