.. currentmodule:: pyb
|
|
.. _pyb.CAN:
|
|
|
|
class CAN -- controller area network communication bus
|
|
======================================================
|
|
|
|
CAN implements support for classic CAN (available on F4, F7 MCUs) and CAN FD (H7 series) controllers.
|
|
At the physical level CAN bus consists of 2 lines: RX and TX. Note that to connect the pyboard to a
|
|
CAN bus you must use a CAN transceiver to convert the CAN logic signals from the pyboard to the correct
|
|
voltage levels on the bus.
|
|
|
|
Example usage for classic CAN controller in Loopback (transceiver-less) mode::
|
|
|
|
from pyb import CAN
|
|
can = CAN(1, CAN.LOOPBACK)
|
|
can.setfilter(0, CAN.LIST16, 0, (123, 124, 125, 126)) # set a filter to receive messages with id=123, 124, 125 and 126
|
|
can.send('message!', 123) # send a message with id 123
|
|
can.recv(0) # receive message on FIFO 0
|
|
|
|
Example usage for CAN FD controller with all of the possible options enabled::
|
|
|
|
# FD frame + BRS mode + Extended frame ID. 500 Kbit/s for arbitration phase, 1Mbit/s for data phase.
|
|
can = CAN(1, CAN.NORMAL, baudrate=500_000, brs_baudrate=1_000_000, sample_point=80)
|
|
can.setfilter(0, CAN.RANGE, 0, (0xFFF0, 0xFFFF))
|
|
can.send('a'*64, 0xFFFF, fdf=True, brs=True, extframe=True)
|
|
can.recv(0)
|
|
|
|
The following CAN module functions and their arguments are available
|
|
for both classic and FD CAN controllers, unless otherwise stated.
|
|
|
|
Constructors
|
|
------------
|
|
|
|
.. class:: CAN(bus, ...)
|
|
|
|
Construct a CAN object on the given bus. *bus* can be 1-2, or ``'YA'`` or ``'YB'``.
|
|
With no additional parameters, the CAN object is created but not
|
|
initialised (it has the settings from the last initialisation of
|
|
the bus, if any). If extra arguments are given, the bus is initialised.
|
|
See :meth:`CAN.init` for parameters of initialisation.
|
|
|
|
The physical pins of the CAN buses are:
|
|
|
|
- ``CAN(1)`` is on ``YA``: ``(RX, TX) = (Y3, Y4) = (PB8, PB9)``
|
|
- ``CAN(2)`` is on ``YB``: ``(RX, TX) = (Y5, Y6) = (PB12, PB13)``
|
|
|
|
Methods
|
|
-------
|
|
|
|
.. method:: CAN.init(mode, prescaler=100, *, sjw=1, bs1=6, bs2=8, auto_restart=False, baudrate=0, sample_point=75,
|
|
num_filter_banks=14, brs_sjw=1, brs_bs1=8, brs_bs2=3, brs_baudrate=0, brs_sample_point=75)
|
|
|
|
Initialise the CAN bus with the given parameters:
|
|
|
|
- *mode* is one of: NORMAL, LOOPBACK, SILENT, SILENT_LOOPBACK
|
|
- *prescaler* is the value by which the CAN input clock is divided to generate the
|
|
nominal bit time quanta. The prescaler can be a value between 1 and 1024 inclusive
|
|
for classic CAN, and between 1 and 512 inclusive for CAN FD.
|
|
- *sjw* is the resynchronisation jump width in units of time quanta for nominal bits;
|
|
it can be a value between 1 and 4 inclusive for classic CAN, and between 1 and 128 inclusive for CAN FD.
|
|
- *bs1* defines the location of the sample point in units of the time quanta for nominal bits;
|
|
it can be a value between 1 and 16 inclusive for classic CAN, and between 2 and 256 inclusive for CAN FD.
|
|
- *bs2* defines the location of the transmit point in units of the time quanta for nominal bits;
|
|
it can be a value between 1 and 8 inclusive for classic CAN, and between 2 and 128 inclusive for CAN FD.
|
|
- *auto_restart* sets whether the controller will automatically try and restart
|
|
communications after entering the bus-off state; if this is disabled then
|
|
:meth:`~CAN.restart()` can be used to leave the bus-off state
|
|
- *baudrate* if a baudrate other than 0 is provided, this function will try to automatically
|
|
calculate the CAN nominal bit time (overriding *prescaler*, *bs1* and *bs2*) that satisfies
|
|
both the baudrate and the desired *sample_point*.
|
|
- *sample_point* given in a percentage of the nominal bit time, the *sample_point* specifies the position
|
|
of the bit sample with respect to the whole nominal bit time. The default *sample_point* is 75%.
|
|
- *num_filter_banks* for classic CAN, this is the number of banks that will be assigned to CAN(1),
|
|
the rest of the 28 are assigned to CAN(2).
|
|
- *brs_prescaler* is the value by which the CAN FD input clock is divided to generate the
|
|
data bit time quanta. The prescaler can be a value between 1 and 32 inclusive.
|
|
- *brs_sjw* is the resynchronisation jump width in units of time quanta for data bits;
|
|
it can be a value between 1 and 16 inclusive
|
|
- *brs_bs1* defines the location of the sample point in units of the time quanta for data bits;
|
|
it can be a value between 1 and 32 inclusive
|
|
- *brs_bs2* defines the location of the transmit point in units of the time quanta for data bits;
|
|
it can be a value between 1 and 16 inclusive
|
|
- *brs_baudrate* if a baudrate other than 0 is provided, this function will try to automatically
|
|
calculate the CAN data bit time (overriding *brs_prescaler*, *brs_bs1* and *brs_bs2*) that satisfies
|
|
both the baudrate and the desired *brs_sample_point*.
|
|
- *brs_sample_point* given in a percentage of the data bit time, the *brs_sample_point* specifies the position
|
|
of the bit sample with respect to the whole data bit time. The default *brs_sample_point* is 75%.
|
|
|
|
|
|
The time quanta tq is the basic unit of time for the CAN bus. tq is the CAN
|
|
prescaler value divided by PCLK1 (the frequency of internal peripheral bus 1);
|
|
see :meth:`pyb.freq()` to determine PCLK1.
|
|
|
|
A single bit is made up of the synchronisation segment, which is always 1 tq.
|
|
Then follows bit segment 1, then bit segment 2. The sample point is after bit
|
|
segment 1 finishes. The transmit point is after bit segment 2 finishes.
|
|
The baud rate will be 1/bittime, where the bittime is 1 + BS1 + BS2 multiplied
|
|
by the time quanta tq.
|
|
|
|
For example, with PCLK1=42MHz, prescaler=100, sjw=1, bs1=6, bs2=8, the value of
|
|
tq is 2.38 microseconds. The bittime is 35.7 microseconds, and the baudrate
|
|
is 28kHz.
|
|
|
|
See page 680 of the STM32F405 datasheet for more details.
|
|
|
|
.. method:: CAN.deinit()
|
|
|
|
Turn off the CAN bus.
|
|
|
|
.. method:: CAN.restart()
|
|
|
|
Force a software restart of the CAN controller without resetting its
|
|
configuration.
|
|
|
|
If the controller enters the bus-off state then it will no longer participate
|
|
in bus activity. If the controller is not configured to automatically restart
|
|
(see :meth:`~CAN.init()`) then this method can be used to trigger a restart,
|
|
and the controller will follow the CAN protocol to leave the bus-off state and
|
|
go into the error active state.
|
|
|
|
.. method:: CAN.state()
|
|
|
|
Return the state of the controller. The return value can be one of:
|
|
|
|
- ``CAN.STOPPED`` -- the controller is completely off and reset;
|
|
- ``CAN.ERROR_ACTIVE`` -- the controller is on and in the Error Active state
|
|
(both TEC and REC are less than 96);
|
|
- ``CAN.ERROR_WARNING`` -- the controller is on and in the Error Warning state
|
|
(at least one of TEC or REC is 96 or greater);
|
|
- ``CAN.ERROR_PASSIVE`` -- the controller is on and in the Error Passive state
|
|
(at least one of TEC or REC is 128 or greater);
|
|
- ``CAN.BUS_OFF`` -- the controller is on but not participating in bus activity
|
|
(TEC overflowed beyond 255).
|
|
|
|
.. method:: CAN.info([list])
|
|
|
|
Get information about the controller's error states and TX and RX buffers.
|
|
If *list* is provided then it should be a list object with at least 8 entries,
|
|
which will be filled in with the information. Otherwise a new list will be
|
|
created and filled in. In both cases the return value of the method is the
|
|
populated list.
|
|
|
|
The values in the list are:
|
|
|
|
- TEC value
|
|
- REC value
|
|
- number of times the controller enterted the Error Warning state (wrapped
|
|
around to 0 after 65535)
|
|
- number of times the controller enterted the Error Passive state (wrapped
|
|
around to 0 after 65535)
|
|
- number of times the controller enterted the Bus Off state (wrapped
|
|
around to 0 after 65535)
|
|
- number of pending TX messages
|
|
- number of pending RX messages on fifo 0
|
|
- number of pending RX messages on fifo 1
|
|
|
|
.. method:: CAN.setfilter(bank, mode, fifo, params, *, rtr, extframe=False)
|
|
|
|
Configure a filter bank:
|
|
|
|
- *bank* is the classic CAN controller filter bank, or CAN FD filter index, to configure.
|
|
- *mode* is the mode the filter should operate in, see the tables below.
|
|
- *fifo* is which fifo (0 or 1) a message should be stored in, if it is accepted by this filter.
|
|
- *params* is an array of values the defines the filter. The contents of the array depends on the *mode* argument.
|
|
|
|
+-----------+---------------------------------------------------------+
|
|
|*mode* |Contents of *params* array for classic CAN controller |
|
|
+===========+=========================================================+
|
|
|CAN.LIST16 |Four 16 bit ids that will be accepted |
|
|
+-----------+---------------------------------------------------------+
|
|
|CAN.LIST32 |Two 32 bit ids that will be accepted |
|
|
+-----------+---------------------------------------------------------+
|
|
|CAN.MASK16 |Two 16 bit id/mask pairs. E.g. (1, 3, 4, 4) |
|
|
| | | The first pair, 1 and 3 will accept all ids |
|
|
| | | that have bit 0 = 1 and bit 1 = 0. |
|
|
| | | The second pair, 4 and 4, will accept all ids |
|
|
| | | that have bit 2 = 1. |
|
|
+-----------+---------------------------------------------------------+
|
|
|CAN.MASK32 |As with CAN.MASK16 but with only one 32 bit id/mask pair.|
|
|
+-----------+---------------------------------------------------------+
|
|
|
|
+-----------+---------------------------------------------------------+
|
|
|*mode* |Contents of *params* array for CAN FD controller |
|
|
+===========+=========================================================+
|
|
|CAN.RANGE |Two ids that represent a range of accepted ids. |
|
|
+-----------+---------------------------------------------------------+
|
|
|CAN.DUAL |Two ids that will be accepted. For example (1, 2) |
|
|
+-----------+---------------------------------------------------------+
|
|
|CAN.MASK |One filter ID and a mask. For example (0x111, 0x7FF) |
|
|
+-----------+---------------------------------------------------------+
|
|
|
|
- *rtr* For classic CAN controllers, this is an array of booleans that states if
|
|
a filter should accept a remote transmission request message. If this argument
|
|
is not given then it defaults to ``False`` for all entries. The length of the
|
|
array depends on the *mode* argument. For CAN FD, this argument is ignored.
|
|
|
|
+-----------+----------------------+
|
|
|*mode* |length of *rtr* array |
|
|
+===========+======================+
|
|
|CAN.LIST16 |4 |
|
|
+-----------+----------------------+
|
|
|CAN.LIST32 |2 |
|
|
+-----------+----------------------+
|
|
|CAN.MASK16 |2 |
|
|
+-----------+----------------------+
|
|
|CAN.MASK32 |1 |
|
|
+-----------+----------------------+
|
|
|
|
- *extframe* If True the frame will have an extended identifier (29 bits),
|
|
otherwise a standard identifier (11 bits) is used.
|
|
|
|
|
|
.. method:: CAN.clearfilter(bank, extframe=False)
|
|
|
|
Clear and disables a filter bank:
|
|
|
|
- *bank* is the classic CAN controller filter bank, or CAN FD filter index, to clear.
|
|
- *extframe* For CAN FD controllers, if True, clear an extended filter (configured with extframe=True),
|
|
otherwise the clear a standard identifier (configured with extframe=False).
|
|
|
|
.. method:: CAN.any(fifo)
|
|
|
|
Return ``True`` if any message waiting on the FIFO, else ``False``.
|
|
|
|
.. method:: CAN.recv(fifo, list=None, *, timeout=5000)
|
|
|
|
Receive data on the bus:
|
|
|
|
- *fifo* is an integer, which is the FIFO to receive on
|
|
- *list* is an optional list object to be used as the return value
|
|
- *timeout* is the timeout in milliseconds to wait for the receive.
|
|
|
|
Return value: A tuple containing five values.
|
|
|
|
- The id of the message.
|
|
- A boolean that indicates if the message ID is standard or extended.
|
|
- A boolean that indicates if the message is an RTR message.
|
|
- The FMI (Filter Match Index) value.
|
|
- An array containing the data.
|
|
|
|
If *list* is ``None`` then a new tuple will be allocated, as well as a new
|
|
bytes object to contain the data (as the fifth element in the tuple).
|
|
|
|
If *list* is not ``None`` then it should be a list object with a least five
|
|
elements. The fifth element should be a memoryview object which is created
|
|
from either a bytearray or an array of type 'B' or 'b', and this array must
|
|
have enough room for at least 8 bytes. The list object will then be
|
|
populated with the first four return values above, and the memoryview object
|
|
will be resized inplace to the size of the data and filled in with that data.
|
|
The same list and memoryview objects can be reused in subsequent calls to
|
|
this method, providing a way of receiving data without using the heap.
|
|
For example::
|
|
|
|
buf = bytearray(8)
|
|
lst = [0, 0, 0, 0, memoryview(buf)]
|
|
# No heap memory is allocated in the following call
|
|
can.recv(0, lst)
|
|
|
|
.. method:: CAN.send(data, id, *, timeout=0, rtr=False, extframe=False, fdf=False, brs=False)
|
|
|
|
Send a message on the bus:
|
|
|
|
- *data* is the data to send (an integer to send, or a buffer object).
|
|
- *id* is the id of the message to be sent.
|
|
- *timeout* is the timeout in milliseconds to wait for the send.
|
|
- *rtr* is a boolean that specifies if the message shall be sent as
|
|
a remote transmission request. If *rtr* is True then only the length
|
|
of *data* is used to fill in the DLC slot of the frame; the actual
|
|
bytes in *data* are unused.
|
|
- *extframe* if True the frame will have an extended identifier (29 bits),
|
|
otherwise a standard identifier (11 bits) is used.
|
|
- *fdf* for CAN FD controllers, if set to True, the frame will have an FD
|
|
frame format, which supports data payloads up to 64 bytes.
|
|
- *brs* for CAN FD controllers, if set to True, the bitrate switching mode
|
|
is enabled, in which the data phase is transmitted at a different bitrate.
|
|
See :meth:`CAN.init` for the data bit timing configuration parameters.
|
|
|
|
If timeout is 0 the message is placed in a buffer in one of three hardware
|
|
buffers and the method returns immediately. If all three buffers are in use
|
|
an exception is thrown. If timeout is not 0, the method waits until the
|
|
message is transmitted. If the message can't be transmitted within the
|
|
specified time an exception is thrown.
|
|
|
|
Return value: ``None``.
|
|
|
|
.. method:: CAN.rxcallback(fifo, fun)
|
|
|
|
Register a function to be called when a message is accepted into a empty fifo:
|
|
|
|
- *fifo* is the receiving fifo.
|
|
- *fun* is the function to be called when the fifo becomes non empty.
|
|
|
|
The callback function takes two arguments the first is the can object it self the second is
|
|
a integer that indicates the reason for the callback.
|
|
|
|
+--------+------------------------------------------------+
|
|
| Reason | |
|
|
+========+================================================+
|
|
| 0 | A message has been accepted into a empty FIFO. |
|
|
+--------+------------------------------------------------+
|
|
| 1 | The FIFO is full |
|
|
+--------+------------------------------------------------+
|
|
| 2 | A message has been lost due to a full FIFO |
|
|
+--------+------------------------------------------------+
|
|
|
|
Example use of rxcallback::
|
|
|
|
def cb0(bus, reason):
|
|
print('cb0')
|
|
if reason == 0:
|
|
print('pending')
|
|
if reason == 1:
|
|
print('full')
|
|
if reason == 2:
|
|
print('overflow')
|
|
|
|
can = CAN(1, CAN.LOOPBACK)
|
|
can.rxcallback(0, cb0)
|
|
|
|
Constants
|
|
---------
|
|
|
|
.. data:: CAN.NORMAL
|
|
CAN.LOOPBACK
|
|
CAN.SILENT
|
|
CAN.SILENT_LOOPBACK
|
|
|
|
The mode of the CAN bus used in :meth:`~CAN.init()`.
|
|
|
|
.. data:: CAN.STOPPED
|
|
CAN.ERROR_ACTIVE
|
|
CAN.ERROR_WARNING
|
|
CAN.ERROR_PASSIVE
|
|
CAN.BUS_OFF
|
|
|
|
Possible states of the CAN controller returned from :meth:`~CAN.state()`.
|
|
|
|
.. data:: CAN.LIST16
|
|
CAN.MASK16
|
|
CAN.LIST32
|
|
CAN.MASK32
|
|
|
|
The operation mode of a filter used in :meth:`~CAN.setfilter()` for classic CAN.
|
|
|
|
.. data:: CAN.DUAL
|
|
CAN.RANGE
|
|
CAN.MASK
|
|
|
|