Browse Source

rp2040: use 4MHz as default frequency for SPI

This matches other SPI implementations. I think the original value of
115200 was from a confusion with UART.
pull/3626/head
Ayke van Laethem 2 years ago
committed by Ron Evans
parent
commit
7d83e76833
  1. 4
      src/machine/machine_rp2040_spi.go

4
src/machine/machine_rp2040_spi.go

@ -136,7 +136,7 @@ func (spi SPI) GetBaudRate() uint32 {
} }
// Configure is intended to setup/initialize the SPI interface. // Configure is intended to setup/initialize the SPI interface.
// Default baudrate of 115200 is used if Frequency == 0. Default // Default baudrate of 4MHz is used if Frequency == 0. Default
// word length (data bits) is 8. // word length (data bits) is 8.
// Below is a list of GPIO pins corresponding to SPI0 bus on the rp2040: // Below is a list of GPIO pins corresponding to SPI0 bus on the rp2040:
// //
@ -152,7 +152,7 @@ func (spi SPI) GetBaudRate() uint32 {
// //
// No pin configuration is needed of SCK, SDO and SDI needed after calling Configure. // No pin configuration is needed of SCK, SDO and SDI needed after calling Configure.
func (spi SPI) Configure(config SPIConfig) error { func (spi SPI) Configure(config SPIConfig) error {
const defaultBaud uint32 = 115200 const defaultBaud uint32 = 4 * MHz
if config.SCK == 0 && config.SDO == 0 && config.SDI == 0 { if config.SCK == 0 && config.SDO == 0 && config.SDI == 0 {
// set default pins if config zero valued or invalid clock pin supplied. // set default pins if config zero valued or invalid clock pin supplied.
switch spi.Bus { switch spi.Bus {

Loading…