The Sync Command
sync
The sync command reestablishes connection with the Target.
Format
The format for the sync command is:
sync
Functional Description
The sync command is used to reestablish connection
after the SerialICE Monitor has reported that it has lost contact
with the target. You must press reset on the target before using this
command.
An Example illustrating the use of the sync command follows.
IMON r Attempt to display GP registers
IMON displays several messages stating that it is unable
to establish connection with the target.
User presses reset on the target.
IMON sync Reestablish connection
IMON r GP registers displayed correctly
zero at v0 v1 a0 a1 a2 a3
$0- 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
t0 t1 t2 t3 t4 t5 t6 t7
$8- 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
s0 s1 s2 s3 s4 s5 s6 s7
$16- 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
t8 t9 k0 k1 gp sp s8 ra
$24- 00000000 00000000 00000000 00000000 00000000 9fffffe8 00000000 00000000
��������������������������������������������������������������������������������